Reference number
ISO 16000-14:2009
International Standard
ISO 16000-14:2009
Indoor air — Part 14: Determination of total (gas and particle-phase) polychlorinated dioxin-like biphenyls (PCBs) and polychlorinated dibenzo-p-dioxins/dibenzofurans (PCDDs/PCDFs) — Extraction, clean-up and analysis by high-resolution gas chromatography and mass spectrometry
Edition 1
2009-05
Read sample
ISO 16000-14:2009
44295
Published (Edition 1, 2009)
This publication was last reviewed and confirmed in 2019. Therefore this version remains current.

ISO 16000-14:2009

ISO 16000-14:2009
44295
Language
Format
CHF 194
Convert Swiss francs (CHF) to your currency

Abstract

ISO 16000-14:2009 specifies extraction, clean-up, and analysis procedures for the determination of polychlorinated biphenyls (PCBs), polychlorinated dibenzo-p-dioxins (PCDDs) and polychlorinated dibenzofurans (PCDFs) collected from indoor air on particle filters backed by polyurethane foam (PUF). The method incorporates specific analyses by high resolution gas chromatography combined with high resolution mass spectrometry (HRGC/HRMS).

The method provides accurate quantitative data for tetra- to decachlorobiphenyls and tetra- to octachloro-dibenzo-p-dioxins/dibenzofurans (total concentrations for each isomeric series). It is capable of detecting 0,2 pg/m3 or lower concentrations of most PCBs and PCDFs/PCDDs with air sampling volumes up to 360 m3 or more in special cases. However, it may not be possible to detect all analytes at 0,2 pg/m3 or lower, especially at lower sampling volumes.

Precision under normal conditions can be expected to be ±25 % or better and uncertainty ±50 % or better.

General information

  •  : Published
     : 2009-05
    : International Standard confirmed [90.93]
  •  : 1
     : 53
  • ISO/TC 146/SC 6
    13.040.20 
  • RSS updates

Got a question?

Check out our Help and Support